The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
;
The manual is useful for trouble shooting for an old instrument. It saved money,and let me enjoy DIY.
;
Perfect source of information for replacing the HDD and performing general diagnostics.
;
Perfect source of information for replacing the HDD and performing general diagnostics.
;
Very good scanned copies. Quick response and reasonable price. Thanks for service!
8.5.
Sleep Mode Auto Operation
Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following movement will start to avoid overcooling. � The fan speed refer to Indoor Fan Motor Control. � The setting temperature will be risen by 0.5°C at the start of operation and by 0.5°C one hour later. � The operation will stop after 8 hours. � When using together with the Timer, the ON-Timer has priority.
Heating Operation When you press the SLEEP Mode, the following movement will start to avoid overheating. � The fan speed refer to Indoor Fan Motor Control. � The setting temperature will be descented by 2°C at the start of operation and by 3°C one hour later. � The operation will stop after 8 hours. � When using together with the Timer, the ON-Timer has priority.
8.6.
Auto Restart Control
� If there is a power failure, operation will be automatically restarted when the power is resumed. It will start with previous operation mode and airflow direction. (Time Delay Safety Control is valid) � Auto Restart Control is not available when Timer or Sleep Mode is set. � This control can be omitted by cutting the jumper wire J2. (Refer Circuit Diagram)
8.7.
Indoor Fan Speed Control
� Auto Fan Speed Control When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table. � Manual Fan Speed Control Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button.
Fan Speed Cooling Soft Dry Manual Auto Sleep Manual, Auto Sleep Manual Auto Sleep O O O O High Speed �� Low Speed O O O O O O O O O O O O Lo SLo SSLo
O O
Heating
O O Hi
O O Me
O STOP
|
|
|
> |
|